Conor Smith, Ph.D.

Introduction: A new modified Schenck SPE QuEChERS method is described below. This method employs a pass-through SPE method and gives good recoveries of 18 GC/MS amenable pesticides while removing the pigment from the spinach extract.

 

Reagents and Chemicals: United Science Schenck QuEChERS tubes with 500 mg CarbonX for QuEChERS and 500 mg of PSA (P/N 1605344173) were used for sample cleanup. Spectral grade Acetonitrile (ACN) from MPBio was used along with glacial acetic acid from Ampresco.

 

Method: Initially, 15 g of spinach (cryo communition) is extracted with 1% acetic acid in ACN (AAACN) and an AOAC QuEChERS salt packet (P/N 1601161160). From this extract, the tube is preconditioned with 2 mL of AAACN under vacuum flow.  This fraction is discarded. Then 3 mL of extract is loaded  under gravity flow and the eluent is collected. Following the initial loading, the cartridge is extracted with 12 mL of AAACN under gravity flow. . The collected ~15 mL is then evaporated to 3 mL and analyzed via GC/MS.  See app note “Analysis of 18 Pesticide Residues in Spinach Using CarbonX for QuEChERS AOAC dSPE Kits by GC/MS” for compelte GC/MS conditions.

 

Recoveries: Recoveries for a 200, 50, and 10 ng/g pesticide spiking experiment are shown below

The SPE QuEChERs method provides good recoveries of all of the pesticides, including planar pesticides such as Chlorothalonil, Dichlorobenzophenone, Folpet, and Coumaphos without the need for toxic solvents such as toluene.

 

GC/MS parameters can be found here and a .pdf of this app can be found here.

 

 

Post By conor (8 Posts)

Sensor and Materials Expert. Graduated in 2011 with a Ph.D. in inorganic chemistry from the University of Minnesota. Currently focused on materials R&D, production synthesis, and custom and automated systems design.

Connect

Share →